HD/K-130 215 WIL

For Cavity widths 130-145mm

The blockwork is built tight against inner face of the steel lintel. Place mortar bed on top of blockwork before floor units are laid to provide even distribution of load. Steel Lintels may be propped to facilitate speed of construction.


Click to Copy Architect Specification

Length (mm) Height
(mm)
Thickness
(mm)
Total UDL
kN 3:1
Total UDL
kN 19:1
Fin Height
600
1500
164 2.5 40 35 175
1650
1800
190 2.9 45 40 225
1950
2100
190 3.2 50 45 225

Manufactured in 150mm increments