S/K-50 215 WIL

For Cavity widths 50-65mm

The blockwork is built tight against inner face of the steel lintel. Place mortar bed on top of blockwork before floor units are laid to provide even distribution of load. Steel Lintels may be propped to facilitate speed of construction.

Click to Copy Architect Specification

Length (mm) Height

(mm)

Thickness

(mm)

Total UDL

kN 3:1

Total UDL

kN 19:1

Fin Height
600
1200
78 2.5 25 20 100
1350
1500
104 2.5 25 20 120
1650
1800
121 2.5 25 20 140
1950
2100
146 2.5 30 25 175
2250
2400
171 2.5 30 25 225
2550
2700
171 2.9 35 30 225
2850
3000
209 2.9 40 35 225
3150
4000
209 2.9 40 35 225
SKU: SK50WIL215 Categories: ,
↓