S/K-50 WIL

For Cavity widths 50-65mm

The blockwork is built tight against inner face of the steel lintel. Place mortar bed on top of blockwork before floor units are laid to provide even distribution of load. Steel Lintels may be propped to facilitate speed of construction.


Click to Copy Architect Specification

Length (mm) Height
(mm)
Thickness
(mm)
Total UDL
kN 3:1
Total UDL
kN 19:1
600
1350
91 1.6 12 10
1500
1650
96 2.0 12 10
1800 110 2.0 15 13
1950
2100
136 2.0 20 18
2250
2400
162 2.0 24 20
2550
3000
172 2.6 28 21
3150
3600
196 3.2 30 26
3750
4000
196 3.2 27 25
4200 196 3.4 26 22
SKU: SK50WIL Categories: ,
↓