Skip to main content

Cavity Wall Steel Lintels

HD/K-70 WIL

HD/K-70 WIL

Outer leaf (mm)

102

Inner leaf (mm)

125-150

Loading conditions

Heavy Duty

Max length

2700

Standard

EN 845-2

Recyclable

100%

HD/K-70 WIL Lintel lengths

NB: The required length of the lintel is the clear opening span plus an additional 150 mm for end bearing on both sides.

Lintel length (mm) Height (mm) Thickness (mm) Total UDL kN 3:1 Total UDL kN 19:1 Add to quote
600 131 2.9 20 17
750 131 2.9 20 17
900 131 2.9 20 17
1,050 131 2.9 20 17
1,200 131 2.9 20 17
1,350 131 2.9 20 17
1,500 156 2.9 35 27
1,650 156 2.9 35 27
1,800 156 2.9 35 27
1,950 194 2.9 30 25
2,100 194 2.9 30 25
2,250 194 3.2 36 32
2,400 194 3.2 36 32
2,550 194 3.2 36 32
2,700 194 3.2 36 32