Skip to main content

Cavity Wall Steel Lintels

S/K-130

S/K-130

Outer leaf (mm)

102

Inner leaf (mm)

100

Loading conditions

Standard

Max length

4800

Standard

EN 845-2

Recyclable

100%

S/K-130 Lintel lengths

NB: The required length of the lintel is the clear opening span plus an additional 150 mm for end bearing on both sides.

Lintel length (mm) Height (mm) Thickness (mm) Total UDL kN 3:1 Total UDL kN 19:1 Add to quote
600 106 2 16 13
750 106 2 16 13
900 106 2 16 13
1,050 106 2 16 13
1,200 106 2 16 13
1,350 106 2 16 13
1,500 106 2 16 13
1,650 118 2 21 18
1,800 118 2 21 18
1,950 131 2 21 17
2,100 131 2 21 17
2,250 166 2.5 25 20
2,400 166 2.5 25 20
2,550 166 2.5 25 20
2,700 166 2.5 25 20
2,850 191 2.9 26 22
3,000 191 2.9 26 22
3,150 192 3.2 26 19
3,300 192 3.2 26 19
3,450 192 3.2 26 19
3,600 192 3.2 26 19
3,750 192 3.2 26 19
3,900 192 3.2 26 19
4,000 192 3.2 26 19
4,200 206 3.2 25 20
4,350 206 3.2 25 20
4,500 206 3.2 25 20
4,650 206 3.2 25 20
4,800 206 3.2 25 20

Need a lintel in a cavity range or length not listed? Contact our specification team today to speak to us about bespoke solutions.

Get technical support

Simply fill out the form with your technical enquiry and our experts will be in touch.

Comprehensive technical support

Scheduling & specification service

Bespoke design service

Knowledgeable experts

Advice on optimum lintel solutions

"*" indicates required fields

Drop files here or
Accepted file types: jpg, jpeg, png, pdf, zip, dwg, Max. file size: 40 MB.

    Get in touch

    Simply fill out the form with your technical enquiry and our experts will be in touch.