XHD/K-150

For Cavity widths 150-165mm

The blockwork is built tight against inner face of the steel lintel. Place mortar bed on top of blockwork before floor units are laid to provide even distribution of load. Steel Lintels may be propped to facilitate speed of construction.


Click to Copy Architect Specification

Length (mm) Height
(mm)
Thickness
(mm)
Total UDL
kN 3:1
Total UDL
kN 19:1
600
1500
160 3.2 45 40
1650
1800
160 3.2 45 40
1950
2100
200 3.2 50 40
SKU: XHDK150 Categories: ,
↓