Place mortar bed on top of blockwork before floor units are laid to provide even distribution of load. Steel Lintels may be propped to facilitate speed of construction.

SKU: HDK50WIL215 Categories: ,

Description

For Cavity widths 50-65mm

Length (mm) Height
(mm)
Thickness
(mm)
Total UDL
kN 3:1
Total UDL
kN 19:1
Fin Height
600
1500
146 2.5 40 35 175
1650
1800
171 2.5 45 40 225
1950
2100
209 2.9 50 45 225
↓