TJ/K-50

For standard loading conditions in 50mm wide thin joint cavity wall construction. To achieve loading figures lintels must be built in as shown with firmly butted perpendicular joints.

SKU: TJK50 Categories: ,

Description

For Cavity widths 50-65mm

Length (mm) Specification Height (mm) Thickness (mm) Total UDL kN Intneral Leaf Total UDL kN Extneral Leaf
600
1500
A 130 5.0 10 3
1650
1800
B 160 5.0 15 5
1950
2100
C 225 3.2 18 8
2550
2700
D 225 5.0 27 9
2850
3000
E 225 5.0 25 10
↓