Place mortar bed on top of blockwork before floor units are laid to provide even distribution of load. Steel Lintels may be propped to facilitate speed of construction.

SKU: HTHD100 Categories: ,

Description

For Cavity widths 90-105mm

Length (mm) Height (mm) Thickness (mm) Total UDL kN 3:1 Total UDL kN 19:1
600
1500
144 2.9 30 22
1650
2400
226 2.9 35 35
2550
3000
226 3.2 35 35
3150
3600
215 2.9 35 32
↓